You have the right to use 14/2 cable for outlets as long as the outlets room on a 15-amp circuit. If the outlets are on a 20-amp circuit, 14/2 wire is no sufficient. You will have to step up to 12/2 cable for every outlets ~ above 20-amp circuits. Using 14-gauge cable (such as 14/2) to wire outlets ~ above a 20-amp circuit can result in overheating and a dangerous electrical fire. Prior to wiring an outlet, make sure to check your breaker crate to uncover the amperage the the circuit you space working on.

You are watching: How many amps is 14 2 wire rated for

*
*

What is 14/2 Wire?

14/2 is a jacketed cable that contains three 14-gauge electric wires. The first is a black color “hot” wire. The 2nd is a white “hot” wire. The third is a environment-friendly or ceiling copper ground wire. 14/2 is offered in spools and is a very common gauge of cable for residential use.

What is 14-Gauge Wire provided For?

14/2 electric wire have the right to be used for outlets and also lights that space on 15-amp circuits. Most commonly, it is provided to strength light fixtures that need low amperage.

14-gauge wire, such together 14/2, is largely used for wiring irradiate fixtures top top 15-amp circuits.You have the right to use 14-gauge wire for outlets top top 15-amp circuits.If your outlet is on a 20-amp circuit, 14-gauge cable is not sufficient. You need to step as much as at the very least 12-gauge wire.

Although 14-gauge wire deserve to be supplied for outlets, it’s an ext common to uncover 12-gauge cable in use for this purpose. This is because 12-gauge cable is the minimum dimension for outlets on a 20-amp circuit. 14-gauge wire can’t manage this amperage. So, it deserve to only be provided for low-amperage outlets.

What is the best Amperage 14/2 Wire can Handle?

14/2 wire deserve to safely be offered on circuits v an amperage approximately 15 amps. It is dangerous and also illegal to usage 14/2 wire on a 20-amp circuit. Selecting the correct cable gauge based upon your circuit amperage is crucial to safe wiring.

15 amps is the maximum amperage 14/2 wire deserve to safely conduct.Never usage 14/2 wire for one outlet ~ above a circuit conducting much more than 15 amps.Check your breaker box to recognize the amperage that the breaker the controls the circuit you room working on.

In bespeak to determine the amperage the the circuit you’re functioning on, locate and open her breaker box. Find the breaker that controls power to the outlet. The amperage should be stamped ~ above the take care of of the breaker. A “15” shows a 15-amp breaker. “20” suggests a 20-amp breaker. You will most likely see higher numbers for circuits provided to power huge appliances.

Can You operation 14-Gauge wire On a 20-Amp Circuit?

Never operation 14-gauge cable on a 20-amp circuit. 14-gauge cable is not rated to command that much electricity. Forcing 14-gauge wire to command 20 amps of power will cause the wire to overheat. In a best-case scenario, the breaker will certainly flip to protect against dangerous overheating, yet this will certainly kill strength to the circuit.

It is dangerous to operation 14-gauge cable on a 20-amp circuit.Using 14-gauge cable on a 20-amp circuit will an outcome in overheating wires, which will flip the breaker or reason an electric fire.Step up to at the very least 12-gauge wire for all 20-amp circuits.

In a worst-case scenario, 14-gauge cable on a 20-amp circuit will certainly overheat so much that it causes an electrical fire. Instead, evaluation the supplies of 12-gauge and also 14-gauge wire for outlets. It’s command to usage at the very least 12/2 wire on 20-amp circuits to prevent dangerous overheating and avert a fire.

How plenty of Outlets deserve to You put On a 14/2 Wire?

A 15-amp circuit wired with 14/2 copper wire deserve to power as much as eight receptacles. “Receptacle” is the hatchet for areas where you deserve to plug in an appliance. Most outlets have two receptacles, while some have four. If you are using standard two-receptacle outlets, you deserve to wire four of them come a solitary 15-amp circuit utilizing 14-gauge electric wire.

14/2 cable on a 15-amp circuit deserve to power 8 receptacles.Since many outlets have actually 2 receptacles, you can generally wire 4 outlets to a solitary 15-amp circuit making use of 14/2 wire.If you desire to put additional outlets ~ above the circuit, step up to a 20-amp outlet through 12/2 wire.

It’s vital to keep in mind that a 20-amp circuit with 12-gauge wire deserve to power 10 receptacles safely—this equates to an extra outlet. If you desire to placed an extra outlet ~ above a circuit, consider upgrading to a 20-amp circuit with heavier wiring.

Can 14/2 cable Be provided For Lights?

Wiring light fixtures is among the finest uses that 14/2 wire. As lengthy as the light is ~ above a 15-amp circuit, you can use 14/2 cable to administer power come it. Simply make sure the light itself requires no more than 15 amps. In many homes, 14/2 is the wire supplied for integrated lights.

14/2 wire deserve to be safely used for lamp wired come 15-amp circuits.Make certain the irradiate you install does not require much more than 15 amps the power.If your light needs more than 15 amps, you’ll have to wire it come a much more powerful circuit with wire heavier 보다 14/2.14/2 is seldom supplied for outlets due to the fact that it can not power details appliances and tools.

Because part appliances (such as home window AC units, shop vacuums, and power tools) need 20 amps of power, many home contractors wire every outlets come 20-amp circuits with 12-gauge wire. 15-amp circuits merely can’t strength these bigger appliances. Just remember to usage outlets and wire rated for 20 amps if you decision to change your circuit breaker and also step approximately a greater amperage.

Can You cable Outlets v 14/2 Romex?

You deserve to use 14/2 Romex cable all over you deserve to safely use conventional 14/2 cable. This way that 14/2 Romex is qualified of powering outlets that space on a 15-amp circuit. If you are wiring outlets top top a circuit v amperage above 15 amps, you’ll must use a heavier Romex cable come comply with electric code.

You deserve to use Romex 14/2 all over it is for sure to use standard 14/2 wire.Romex 14/2 can be offered to cable outlets on a 15-amp circuit.Never use Romex 14/2 wire to wire outlets top top a circuit v amperage higher than 15.

Remember, Romex cable is merely 14-gauge cable in a nonmetallic cable sheath. This sheath makes it easier for friend to pull the cable through conduits, but it walk not adjust the conducting ability of the cable itself. Romex 14/2 and also standard 14/2 have the right to be provided interchangeably.

What size Wire have to Be offered to run an Outlet Circuit?

What dimension wire you use for her outlet depends generally on the amperage of the circuit. Here are the rules because that 14/2 wire:

14/2 wire have the right to be provided to wire outlets ~ above circuits conducting 15 amps or lower.14/2 cable cannot be supplied to cable outlets ~ above 20-amp circuits.12/2 wire have the right to be provided on both 15-amp and also 20-amp circuits.

See more: What Is The Genre Of Diary Of A Wimpy Kid Cabin Fever Setting

If she unsure that what wire to use for your job, above a licensed electrician. It’s essential to usage a heavy enough wire for your outlet to prevent a possible electrical fire.